Chevrolet: Impala Bi-Fuel Tested with Fire and Bullets
By Mike Garcia
CNG, or Compressed Natural Gas comes with a few hazards. The modern car has coped with the same hazards, and adjusted to create safety over time. Chevrolet took their testing to another level.
A large piece of cast aluminum helps protect the tank valve and connection from certain side impacts. Sheet metal plates on either side of the tank help protect it from loose objects in the trunk or rear seat.
More from Art of Gears
- 3 Reasons the 2024 Mazda CX-50 Is Among the Best Small SUVs
- The Jeep Renegade Is Discontinued: Here’s a Look at Its Legacy
- 2023 Nissan Armada: A Decent Full Size SUV With 1 Glaring Issue
- Best Minivans: 3 Options for Families With Solid Performance
- Here’s Why the 2023 Ford Mustang Mach-E Is So Popular
“We designed this system for those ‘what if’ situations,” said Nichole Kraatz, Impala chief engineer. ”The customer shouldn’t even know it’s there. They shouldn’t even think about it. CNG should just be another fuel they use to power their vehicle.”
Durability and safety testing at the tank’s normal operating pressure of 3,600 PSI and higher subjected it to normal and extreme situations, exceeding federal requirements and CNG industry guidelines. For example:
- The industry-standard Bonfire Test confirms the CNG tank’s pressure relief valves are operational and help prevent the tank from rupturing in a fire. In addition to placing the tank about four inches above a steady 800-degree Fahrenheit fire, General Motors’ engineers added trunk, back seat and underbody fires to test the pressure relief valves’ ability to sense heat on all sides of the tank. And the tests were done at two different fuel levels.
- In the Penetration Test, the tank is filled to its service pressure and is shot with a 7.62 mm armor-piercing bullet. In order to pass the test, the bullet has to pass completely through one side of the tank without exiting out the other side. The goal is to have the tank maintain the bullet hole only as the weak structural point, without rupturing.
- Front barrier, side impact and rear impact crash tests were conducted on the Bi-Fuel Impala. Some aftermarket CNG-conversion kit manufacturers conduct only a barrier test.
The tank also undergoes long-term structural integrity tests equivalent to 15,000 pressure cycles and hydrostatic bursting tests of up to 8,100 PSI.
The all-steel trunk-mounted CNG tank holds approximately 7.8 gallons, sufficient for about 150 miles of driving after which the Impala seamlessly switches to gasoline power.
The complete CNG system is covered by Chevrolet’s five-year, 100,000-mile – whichever comes first – limited powertrain warranty and can be serviced at Chevrolet dealerships throughout the U.S. and Canada.